Range 1: 0 1000 kg (when calibrating set scale interval: 1 kg)
Range 2: 0 2000 kg (next highest scale interval: 2 kg)
Range 3: 0 3000 kg (next highest scale interval: 5 kg)
7.12.15.2
Multi-interval scale (Class III or single range scale Class I and II with variable scale interval)
The multi-interval scale is a scale with a weighing range that is divided into intervals. Each
interval range has a different scale interval, where the weighing range is automatically
switched depending on the load on the scale and also when the load is placed on/
removed from the scale.
When [Range mode] = [Multi-interval], the scale has up to three ranges with different
resolution.
The weight display header includes the current interval range (R1, R2, or R3), Max, Min,
and d (or e with instruments used in legal metrology) (Example: multi-interval scale in
range 2):
The parameters [Range limit 1] and [Range limit 2] are the interval ranges.
1.
Choose "Range mode" from the
-[Weighing point]- [Calib]- [Param] menu.
2.
Select "Multiple range" and confirm.
3.
Setting Switch point from range 1 to 2: enter "1000 kg" for the Range limit 1.
4. Setting Switch point from range 2 to 3: enter "2000 kg" for the Range limit 2.
5.
Press the
softkey to exit and save calibration.