12.3.5.1
PLC → write window EasyFill
Bytes 0 63
Name
Type of data
Function
Byte 0
TableSelect
USINT
The first byte controls (multiplexes) the da-
ta written in the read window by the device.
A "0" describes the read window according
to the system data layout.
A "1" copies the material data to the read
window.
Byte 1
Bit 0: MSB
Bit 0: start filling
Bit 1: stop filling
Bit 2: restart filling
Bit 3: cancel filling
Bit 4: load material and start fil-
ling
Bit 5: print last filling result
Bit 6: reserved
Bit 7: reserved
BOOL
Bit 0:
EasyFill adopts the sent material parame-
ters from byte 4 with the rising edge of this
bit. A valid set point (byte 4 7) that can be
coded as DINT or REAL is required.
The filling process can be started when the
ready bit is set.
Bit 1:
rising edge during filling
Bit 2:
rising edge in the stop status (hold state)
Bit 3:
rising edge in the stop status (hold state)
Bit 4:
rising edge: A valid material ID is required
in byte 3.
Bit 5:
rising edge: The printout of the last filling
result starts.
Byte 2
Bit 0: reset power failure (power
fail)
Bit 1: reset error
Bit 2: weights as DINT
Bit 3: zero
Bit 4: tare
Bit 5: reset tare
Bit 6: filling mode
Bit 7: read material from the
material table
BOOL
Bit 0:
rising edge
Bit 1:
rising edge: resets the error flag and error
code.
Bit 2:
status-controlled:
Value: 0 = Real, 1 = DINT
Bit 3:
rising edge
Bit 4:
rising edge
Bit 5:
rising edge
Bit 6:
status-controlled: 0 = fill, 1 = empty
Bit 7:
rising edge: A valid material ID is required
in byte 3. Filling does not start.
This function can be used to display materi-
al parameters on external displays.
12 Fieldbus interface
Transmitter Series PR 5220
EN-205
Minebea Intec