7.12.3.2
Modifying a calibration
Note:
[Modify] may be used only for minor changes (e.g. changing the dead load, adapting
mV/V values for dead load and/or Max). Otherwise, always use [New]!
Example:
Resetting the Dead Load
7.
Calibrating with load [Max at], see Chapter
8. Calibrating with mV/V [Max at], see Chapter
.
9. Calibrating with load cell data (smart calibration) [Max at], see Chapter
10. Carrying out linearization, see Chapter
1.
Select
-[Weighing point]- [Calib] and confirm.
2.
Press the [Modify] softkey.
3.
Choose the [Deadload at] menu item.
4. Either press the [by mV/V] softkey to enter the value again or clear the scale/hopper
and press the [by load] softkey to reset the dead load.
5.
Press
to exit the calibration.
A prompt window opens.
7 Commissioning
Transmitter Series PR 5220
EN-77