— Filling
— Material ID
Material identification
Selection: ID 1 10
— Material name
Material name
Input: max. 18 alphanumeric characters
— Set point
Set point
Input: weight; adopt unit from the calibration.
— Preset
Preset point for switching from coarse flow to
fine flow. Input: weight; adopt unit from the
calibration.
— Overshoot (OVS)
Material overshoot
Input: Weight; adopt unit from the calibration.
— +/- tolerance
Tolerance above/below set point
Input: tolerance values; adopt unit from the
calibration.
— Calming time
Calming time
Input: in ms
— Start
Start filling.
— Stop
Stop filling.
— Restart
Restart filling.
— Abort
Abort filling.
— Configuration
— Configuration mode
Configure the mode
6
"EasyFill" application
6.1
Functions
6.1.1
General information
The "EasyFill" application is used for single-component filling.
The application allows for quick and reliable filling and emptying of containers.
The filling process can be started, stopped, canceled, and restarted via the VNC user
interface, digital inputs, OPC/Modbus, and fieldbus (except CC-Link).
6.1.2
Display functions
-
Display of gross, net or tare weight
-
Tare/reset tare
-
Set gross to zero
-
Display of weight values or remote display
-
Functions via digital inputs and outputs
-
Information interchange via serial I/O, fieldbus and network
6.1.3
Filling mode
The "EasyFill" application supports the following filling modes:
-
Net filling "B1"
-
Net discharge "B4"
6.2
Application menu [Start]
6 "EasyFill" application
Transmitter Series PR 5220
EN-55
Minebea Intec