12.3.4.2.2 Restarting filling
Requirements:
The system stops, i. e., the Hold_state bit is active.
Example:
Set stop bit with 0010 0000 in byte 1.
Filling starts again with the rising edge and the system leaves the hold status (hold state)
and continues filling.
12.3.4.2.3 Canceling filling
Requirements:
The system stops, i. e., the Hold_state bit is active.
Example:
Set cancel bit with 0001 0000 in byte 1.
Filling starts again with the rising edge and the system leaves the hold status (hold state)
and goes back to the ready status (ready/idle).
12.3.4.3
Filling report
The filling results are stored after filling and only overwritten when there is a new result.
12.3.4.4
Filling error
Last_Error
The last error number is retained until it is reset.
The possible error numbers are listed in Chapter
12.3.4.5
Reading the material table
The material parameters can be read from the material table of the device (PR 5220).
Procedure:
12.3.5
Setup of the fieldbus interface
For description of the data types see Chapter
.
1.
Write the material ID to byte 3.
2.
Write command 1 to byte 0 in order to see the material parameters on the read side.
3.
Write command 0000 0001 to byte 2 in order to copy the material parameters from
the material table.
If all parameters of the material were available to be read, 1000 0000 is set to
byte 2.
4. Write command 0 to byte 0 in order to see the filling parameters again on the read
side.
Transmitter Series PR 5220
12 Fieldbus interface
Minebea Intec
EN-204
Содержание PR 5220 Series
Страница 26: ...3 6 Overview of connections 3 Device description Transmitter Series PR 5220 EN 23 Minebea Intec ...