Inverse switch
Switches the between normal and inverse expander modes.
Attack/Release/Hold controls
The
Expander Section
uses the settings of the
Attack/Release/Hold
controls in the
Dynamics Section
to control
it’s timing.
Equalizer section
A fully parametric five band equalizer. Each band covers the entire frequency range from 20 Hz to 20 kHz (or
higher, depending on the sampling rate of the project) and can be switched between peaking, high or low shelv-
ing and low-pass or high-pass characteristics. Each of the five bands can be switched off. De-activated bands do
not consume DSP power.
Show/ Hide EQ Section
EQ section on/off
Pre Dynamics Switch
This switch offers the option to the switch the EQ before the dynamics section. By default the EQ is after the
dynamics section.
Graphic Display Window
This small window displays the settings of the currently selected EQ band in blue color and the resulting curve of
the whole EQ section in gray color. You can click and drag directly onto the handles (the small blue or gray points)
of the EQ bands to change the settings within the graph window.
Double-click anywhere in the window to open a bigger version. Please see
The Big Graph Window on page 65
.
Threshold
Input level
Output level
Threshold
Input level
Output level
Expander normal mode
Inverse mode
EQ Section On/Off
Band Filter Type
Band Selector
Gain Control
Frequency Control
Show/Hide EQ Section
Pre-Dynamics Switch
Graphic Display Window
Selected Band On/Off
Q (Bandwidth) Control