4-40
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Remove the rear panel (See page 4-36).
Press the locking tab and remove the wire
connector from the sensor.
Pull the temperature sensor out of the tub
with a slight twisting motion.
1.
2.
3.
4.
5.
reMOve TeMPeraTure SenSOr
Remove and replace the grommet only if
necessary.
When installing a grommet, the flanges of
the grommet must seal inside and outside of
the hole in the outer tub.
It is easier to reinstall the grommet once it is
separated from the sensor.
It may help to wet the temperature sensor
when reinstalling it since it is a tight fit in the
rubber grommet.
6.
n
n
n
Temperature
Sensor
Rubber
Grommet
Temperature
Sensor
Содержание MLE20PDAYW0