![Maytag MLE20PDAYW0 Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/maytag/mle20pdayw0/mle20pdayw0_service-manual_1751166068.webp)
4-12
Remove the T-20 screw, on the back of the
washer, that secures each water inlet valve.
From inside of the washer, twist the valve
body to align the locking tabs with the cut-
outs in the back panel. Pull the valve out of
the hole in the panel.
The screens inside the water inlet valve
can be cleaned from the rear of the washer
without removing the water inlet valve.
nOTe:
(See page 4-13) for photos and for
how to remove the water inlet valves from
the back without removing the dryer and
how to clean the screens.
7.
8.
9.
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Remove the washer hoses from the hot and
cold water inlet valves.
Remove dryer from stack (See page 4-11).
Lift the locking tabs and disconnect the wire
connectors to the water inlet valves. The
blue connector is for the hot water valve #1,
the white connector is for bottom cold water
valve #3 and the grey connector is for top
cold water valve #2.
Loosen the clamp and disconnect the hose
from each water inlet valve.
1.
2.
3.
4.
5.
6.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
reMOve WaTer inleT valveS
Water Inlet
Valves
Locking Tab
Inlet Hoses
& Clamps
Water Inlet
Valve Screws