4-33
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Remove the washer lower service panel
(See page 4-26).
Remove the drip cover by lifting it off the
CCU. There are metal tabs on the bracket
that fit into slots at front and back of cover.
1.
2.
3.
4.
Use a small flat blade screwdriver to lift the
locking tab that secures CCU to the washer.
Slide the CCU towards the front of the
washer to release tabs from keyhole slots in
the bracket, in the base of the washer, and
remove it.
Release the wire clips by pressing down
and sliding the tab of the clip out from under
the hook.
Use a small flat blade screwdriver to press
the locking tab that secures each wire
connector to the CCU, and remove the
connectors.
5.
6.
7.
8.
reMOve WaSHer CenTral COnTrOl uniT (CCu)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Tab Slots
Locking Tab
Wire Clips