4-16
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Remove the rear panel (See page 4-36)
or
Remove dryer from stack (See page 4-11).
Disconnect the wire harness by pressing the
locking tabs and pulling the wire harness off
the pressure switch.
1.
2.
3.
4.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
reMOve PreSSure SWiTCH
Rotate the pressure switch 90 degrees and
pull the rectangular tab out of the slot in the
top of the washer side panel.
Disconnect the air hose on the bottom of the
pressure switch, there is no clamp, just a
pressure fit.
nOTe:
Hose should be snug to avoid air
leaks, check for loose or cracked hose end.
TeCH TiP:
Pressure switch may be
removed from the rear of the washer without
removing the dryer. Remove the washer
rear panel, reach inside to access the
pressure switch. Remove the air hose from
the switch and twist the pressure switch 90
degrees to remove it from the side panel.
Disconnect the wire harness plug and
remove it from the rear of the washer.
5.
6.
Pressure
Switch
Pressure
Switch
Wire
Harness
Air Hose
Key
Slot