5-14
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
FlaMe SenSOr
HiGH TeMP THerMOSTaT
& HiGH TeMP CuTOuT
(GaS DryerS Only)
Unplug dryer or disconnect power.
Turn off gas supply to dryer.
Remove flame sensor (See page 4-82).
Disconnect the wire connectors from the
flame sensor terminals.
Set the ohmmeter to the R X 1 scale.
Set digital ohmmeters to lowest scale.
Touch the ohmmeter test leads to the flame
sensor terminals. The meter should indicate
a closed circuit (0 Ω) when cold.
nOTe:
If the ignitor stays on longer than 40
seconds, replace the Radiant Sensor.
1.
2.
3.
4.
5.
6.
Unplug dryer or disconnect power.
Turn off gas supply to dryer.
Remove High temp thermostat
(See page 4-82) or high temp cutout
(See page 4-83).
Disconnect wire connectors from High temp
thermostat and high temp cutout terminals.
Set the ohmmeter to the R X 1 scale.
Set digital ohmmeters to lowest scale.
Touch the ohmmeter test leads to the
High temp thermostat or high temp cutout
terminals. The meter should indicate a
closed circuit (0 Ω).
1.
2.
3.
4.
5.
6.
The high temp cutout is a non-resettable
device. The cutout temperature is 352º F
(178º C).
High Temp Thermostat
High Temp Cutout
Terminals
Terminals
Flame Sensor
Terminals