![Maytag MLE20PDAYW0 Скачать руководство пользователя страница 143](http://html.mh-extra.com/html/maytag/mle20pdayw0/mle20pdayw0_service-manual_1751166143.webp)
4-87
If element is serviceable, remove electric
heater assembly (See page 4-86).
Remove the 1/4” hex head screw from the
bottom of the housing.
Slide mounting bracket tab out of slot in the
housing and remove it.
1.
2.
3.
reMOve HeaTer COil
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Mounting Bracket Tab
1/4” Hex Head Screw
nOTe:
Heater element assemblies have a
serviceable electric coil element. Since the
element is serviceable: remove the heater
coil from the housing using one pair of
pliers to hold the housing and another pair
of pliers to pull the heater coil up out of the
housing.