4-17
Unplug washer or disconnect power.
Turn off the water supply to the washer.
Remove dryer from stack (See page 4-11)
or remove the two brackets from the back
panel that secure the dryer to the washer,
tilt the dryer forward from the back, block
the dryer up and remove the back panel.
Remove the T-20 1/4” hex head screw from
the top of the back right corner brace.
1.
2.
3.
4.
Slide the RFI line filter toward the water inlet
valves to release the tabs in the slots.
Power goes into the RFI line filter through
the L1 and Neutral wire connectors. Power
goes out through two pink wires to the CCU
and the UIC transformer.
Press the locking tab and remove the
connector for the pink wires.
Pull the L1 and neutral wire connectors off
their spade terminals.
nOTe:
Problems can occur with this washer
if the AC power is connected with reverse
polarity. When properly installed the neutral
wire connector should be toward the front
of the washer as viewed from the RFI filter
installed orientation.
To test for proper polarity, power must be
reconnected to the washer, test between the
neutral wire connector and any chassis ground
connection with a volt meter. If the polarity is
correct there should be no voltage present.
Disconnect the washer from the power before
proceeding.
5.
6.
7.
8.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
reMOve rFi line FilTer
RFI Line
Filter
L1
Pink Wires
Out To CCU
Neutral
T-20 Screw
RFI Line Filter
4 Tabs
In Slots
Содержание MLE20PDAYW0