5-8
9 Button User Interface Membrane Switch
Contact
Contact
Button
3
6
A
3
5
B
3
4
C
2
6
D
2
5
E
2
4
F
1
6
G
1
5
H
1
4
I
uSer inTerFaCe MeMBrane SWiTCH
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
See page 4-9 for the procedure for accessing
the keypad assembly.
Unplug washer or disconnect power.
Set the ohmmeter to the R X 1 scale.
Set digital ohmmeters to lowest scale.
Touch the ohmmeter test leads to the
contacts listed. Press the button listed for
each pair of contacts. The meter should
indicate continuity (0 Ω). If the meter
indicates an open circuit (infinite Ω), replace
the membrane switch.