47DAC OPERATING MANUAL EM-9518-B Rev.4
3
Press Shift button to shift the display into the setting standby
mode. Then press Shift and Up buttons to set the LL (L, H, HH
or P) one-shot output.
• The forth digit starts blinking, to which you can apply changes.
• Set within the range of 0000 to 9999.
NOTE
The decimal point is not indicated. Set as ‘setting value × 100 milliseconds’.
4
Press Alarm/
↓
or Scale/
↑
button to apply the new setting.
• And the next parameter setting is indicated.
NOTE
• Press Alarm/
↓
button, and the LL (L, H, HH or P) coil at alarm will be indicated (‘RELAYLL’, ‘RELAY L’, ‘RELAY H’, ‘RE-
LAYHH’ or ‘RELAY P’ on the SD).
• Press Scale/
↑
button, and the LL (L, H, HH or P) OFF delay time will be indicated (‘OFDLYLL’, ‘OFDLY L’, ‘OFDLY H’,
‘OFDLYHH’ or ‘OFDLY P’ on the SD).
5
■
TO GO ON TO SET ANOTHER OFF DELAY TIMES,
Repeat operation from Step 2.
■
TO SET THE NEXT PARAMETER,
Skip to Step 2 in “9.8 ALARM OUTPUT LOGIC (coil energized or de-energized at alarm)”.
■
TO QUIT,
Hold down Alarm/
↓
or Scale/
↑
button for 1 second or more to return to Measuring Mode.
Blinking