SA985, SA975, SA935, SA915 

SG985, SG884, SG834, SG814  

SL987, SL957, SL937, SL917, SL907 

 

Frequency & Phase Meter  

Instruction Manual 

Analog Arts Inc.   

www.analogarts.com

 

Summary of Contents for SA975

Page 1: ...P a g e 1 SA985 SA975 SA935 SA915 SG985 SG884 SG834 SG814 SL987 SL957 SL937 SL917 SL907 Frequency Phase Meter Instruction Manual Analog Arts Inc www analogarts com ...

Page 2: ...Instruction 3 Front Back Panel Items 3 Initiating the Instrument 4 Calibration Sequence 4 Menu Panel 4 Frequency Phase Analyzer Panel 5 Channel 1 Channel 2 Frequency Panels 5 Phase Jitter Panels 5 Reference Channel Panel 6 Utility Panel 6 Save Screen 6 Recall Screen 6 Print 6 Help 6 Glossary 7 ...

Page 3: ... Do not use this instrument in strong magnetic fields 5 Do not apply the instrument to voltages exceeding the maximum rating Operation Instruction This section contains the required information to operate Analog Arts frequency phase analyzer and reviews its associated options Front Back Panel Items The following diagram shows the position of CH1 channel 1 input CH2 channel 2 input TRIG oscilloscop...

Page 4: ...art the device goes through a calibration phase which takes about one minute to complete Subsequently a menu panel opens up Menu Panel After the calibration process is finished a menu appears which lists the instruments included in the unit To start the frequency and phase analyzer click on the Freq Phase Analyzer The frequency and phase analyzer is now ready to test frequencies on channels 1 and ...

Page 5: ...hannel 2 jitter in seconds 6 Reference frequency 7 Utility panel Channel 1 Channel 2 Frequency Panels The frequencies of channel 1 and 2 signals are continuously measured and displayed in their corresponding panels Phase Jitter Panels The phase difference between channel 1 and 2 signals is displayed both in seconds and degrees in their corresponding panels Additionally the jitter between the 2 cha...

Page 6: ...ul functions listed below Save Screen Save Screen saves a desired screen to be used as reference in future measurements Recall Screen Recall Ref displays a previously saved reference for comparison purposes Print Print prints the instrument window by the user specified printer Help Help opens the Analog Arts Help section where the user can access view various topics documentations and or ask his q...

Page 7: ...axis of the oscilloscope Envelope The outline of a signal s highest and lowest points acquired over many displayed waveform repetitions Frequency The frequency equals 1 period Ground A voltage reference usually taken as a point of zero electrical potential or voltage Hertz Hz The unit of frequency which is measured by one cycle per second Marker Horizontal or vertical visible displays that can be ...

Page 8: ...e signal must reach before the trigger circuit initiates a sweep Trigger Mode A mode that determines how the oscilloscope draws a waveform upon detecting a trigger transient mode Common trigger modes include normal and auto Trigger Slope The slope that a trigger source signal must reach before the trigger circuit initiates a sweep Units Dimensions of the measured quantities In oscilloscope units r...