2.3.32 RELAY
R?
indicates the control over the relays. Two outputs
are possible:
Yes
the relays will be controlled via the interface
No
the relays will be controlled by the Monitor.
R? 1
indicates the condition of the relays, when the relay
number is included, for example, R? 1, then
condition of Relay 1 will be readout. Two outputs are
possible:
Yes
active
No
inactive
/***** PROTECTED 59 *****/ (see section
2.3.14 )
The control over the relays can be set using R, If the number is left out, for
example:
R,Y
Yes the relays will be controlled via the interface
No the relays will be controlled by the Monitor.
The relay(s) condition can be set using R. If the relay number is specified,
for example:
R 1,Y
Then the relay specified can be set as shown below:
Yes active