MERLIN LEGEND Communications System Release 5.0
Feature Reference
555-650-110
Issue 1
June 1997
Features
Page 348
Integrated Administration
If
Message Drop
is selected:
■
Add the label
AUDIXVP
to or delete it from the Message Drop extension(s).
■
Add the label
AUDIXVP
to the Message Drop calling group (7928) when the
first Message Drop extension is added, or delete the label when the last
Message Drop extension is deleted.
■
Set the group type to Integrated VMI for the Message Drop calling group
when the first Message Drop extension is added, or set it to Auto Logout
when the last Message Drop extension is deleted.
■
Set the hunt group type to Circular for the Message Drop calling group
when the first Message Drop extension is added.
■
Add Message Drop extension(s) to or delete them from the Message Drop
calling group.
■
Delete all lines from the Message Drop calling group when the last
Message Drop extension is deleted.
If
Voice Mail
is selected:
■
Add the label
AUDIXVP
to or delete it from Voice Mail extension(s).
■
Add label
AUDIXVP
to Voice Mail calling group (7925) when first Voice Mail
extension is added; or delete label when last Voice Mail extension is
deleted.
■
Set the group type to Integrated VMI for the Voice Mail calling group when
the first Voice Mail extension is added, or set it to Auto Logout when the
last Voice Mail extension is deleted.
■
Set the hunt group type to Circular for Voice Mail calling group.
■
Add Voice Mail extension(s) to or delete them from the Voice Mail calling
group.
■
Add Voice Mail extension(s) to or delete them from the Night Service
exclusion list.
■
If Automated Attendant is not selected, add the AUDIX Voice Power
coverage group (30) to the Voice Mail calling group when the first Voice
Mail extension is added.
■
Delete all lines from the Voice Mail calling group when the last Voice Mail
extension is deleted.
Screen Results
2
5
On initial installation of IS III
, after the System Programming/Switch Admin Form
screen, the program steps through the applicable screens shown in Figures
through
, depending on the services selected on this form.
On subsequent access
, after the System Programming/Switch Admin Form
screen, the AUDIX Voice Power or AUDIX Voice Power/Fax Attendant menu
returns. The user can then access the screens shown in Figures
through