MERLIN LEGEND Communications System Release 5.0
Feature Reference
555-650-110
Issue 1
June 1997
Features
Page 237
Display
Feature
Description
Sample Displays
Analog Multiline MLX
Conference
continued
During the conference, the
number of participants is shown
on Line 1 of the display. The
conference originator can view
Caller ID or ISDN calling party
information, if available,
associated with any participant
by pressing the Inspct button
and the button the caller is on.
No display
Conference: 3
OUTSIDE 555-1234
Coverage
When a call is sent to coverage,
the person who answers the
call sees a message on the
display, indicating for whom the
call is intended and the reason
why the call is being sent to
coverage:
All telephones:
No Answer
Busy
Do Not Disturb on
MLX telephones
(additional reasons):
Invalid/unknown DID
number
Invalid/unknown remote
access (DISA) number
MLX telephones also show the
caller’s information on Line 2 of
the Home screen.
Cov No A JUAN
Cov Bsy JUAN
Cov DND JUAN
No display
No display
No display
Cover JUAN No Ans
Cover JUAN Busy
Cover JUAN DND
DID#?
DISA#?
Caller: FX-NYC Trk825
CTI Link
In Release 5.0 and later
systems, an MLX extension
programmed as a CTI link has
its extension label changed.
CTILINK
CTILINK
Date and
Time
An analog multiline telephone
user can set the date and time
on the display. On MLX
telephones, the date and time
are controlled by the system
time.
3:00p We 4-01
Apr 01 3:00