![Lucent Technologies MERLIN LEGEND Release 5.0 Скачать руководство пользователя страница 371](http://html1.mh-extra.com/html/lucent-technologies/merlin-legend-release-5-0/merlin-legend-release-5-0_feature-reference_1946508371.webp)
MERLIN LEGEND Communications System Release 5.0
Feature Reference
555-650-110
Issue 1
June 1997
Features
Page 339
Integrated Administration
System Programming Results
2
5
The following information is sent to the system:
■
Reliable Disconnect setting
■
Delay Ring value
■
Coverage Delay Ring value
■
VMS Transfer Return Interval setting
■
Transfer Return Time setting
Screen Results
2
5
After the Application Switch Defaults screen, press
(
Save
); the Technician
Maintenance menu returns.
Extension Directory Setup
2
5
When the technician selects
Extension Directory Setup
from the Technician
Maintenance menu during installation, IS III checks whether the system Extension
Directory already exists in the application database. If the directory does not exist,
IS III reads the switch extensions into the database, together with the label for
each extension, if there is one. If the directory does exist, the technician has the
following choices:
■
Exit without making any changes to the database, using
(
Cancel
).
■
Reinstall the database. This choice completely replaces the existing
Extension Directory in the application database.
■
Reconcile the database with the switch. This choice follows the same rules
as the daily reconciliation program, as described earlier in
System Programming Results
2
5
No information is sent to the switch.