Learning Advanced Features
212
•
If the value for AP2-48 Pre Heat Curr is above the rated motor current value, it is limited by
the rated motor current value.
•
If the value for AP2-48 Pre Heat Curr is too high or the DC current output time is too long
,
the motor may overheat or be damaged and the Inver IOLT may also malfunction. Reduce
the DC output current amount and DC output time to prevent from such damages.
5.21 Auto Tuning
The motor parameters can be measured automatically and can be used for an auto torque
boost.
Example - Auto Tuning Based on 5.5 kW, 200 V Motor
Group Code Name
LCD Display
Parameter Setting Setting Range
Unit
DRV
14
Motor capacity
Motor
Capacity
9 5.5 kW
7–20
-
BAS
11
Motor pole
number
Pole Number 4
2–48
-
12
Rated slip speed Rated Slip
45
0–3000
Rpm
13
Rated motor
current
Rated Curr
21.0
1.0–1000.0
A
14
Motor no-load
current
Noload curr
7.1
0.5–1000.0
A
15
Motor rated
voltage
Rated Volt
220
170–480
V
16
Motor efficiency Efficiency
85
70–100
%
20
Auto tuning
Auto Tuning
0 None
-
-
21
Stator resistance Rs
0.314
Depends on
the motor
setting
Ω
22
Leakage
inductance
Lsigma
3.19
Depends on
the motor
setting
mH
Содержание LSLV0055H100-4COFN
Страница 14: ......
Страница 18: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Страница 27: ...Preparing the Installation 13 ...
Страница 47: ...33 Installing the Inverter ...
Страница 48: ...Installing the Inverter 34 Input and Output Control Terminal Block Wiring Diagram ...
Страница 61: ...47 Installing the Inverter ...
Страница 71: ...Learning to Perform Basic Operations 57 ...
Страница 88: ...Learning to Perform Basic Operations 74 ...
Страница 103: ...89 Learning Basic Features Code Description V1 Quantizing ...
Страница 120: ...Learning Basic Features 106 Grou p Cod e Name LCD Display Parameter Setting Setting Range Unit Prev ...
Страница 129: ...115 Learning Basic Features ...
Страница 140: ...Learning Basic Features 126 ...
Страница 148: ...Learning Basic Features 134 ...
Страница 171: ...157 Learning Advanced Features Deceleration dwell operation ...
Страница 183: ...169 Learning Advanced Features ...
Страница 184: ...Learning Advanced Features 170 PID Command Block ...
Страница 185: ...171 Learning Advanced Features PID Feedback Block ...
Страница 186: ...Learning Advanced Features 172 PID Output Block ...
Страница 187: ...173 Learning Advanced Features PID Output Mode Block ...
Страница 197: ...183 Learning Advanced Features ...
Страница 201: ...187 Learning Advanced Features Code Description 100 EPID1 Control block ...
Страница 202: ...Learning Advanced Features 188 EPID2 Control block ...
Страница 237: ...223 Learning Advanced Features Time Period Schedule AP3 38 Except3 Day 01 01 ...
Страница 244: ...Learning Advanced Features 230 ...
Страница 259: ...245 Learning Advanced Features Code Description Code Description Volt ...
Страница 362: ...Learning Protection Features 348 ...
Страница 415: ...401 RS 485 Communication Features Item Standards Parity check None ...
Страница 524: ...Table of Functions 510 ...
Страница 533: ...Table of Functions 519 ...
Страница 547: ...533 Troubleshooting ...
Страница 564: ...Technical Specification 550 11 3 External Dimensions IP 20 Type 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Страница 585: ...Technical Specification 571 ...
Страница 594: ...580 ...
Страница 595: ...581 ...
Страница 596: ...582 ...