General information
ProtoMat C30/C30-S
13
3.4 Installation
› Unpack the LPKF
ProtoMat C30 (C30/S)
carefully. Remove the
securing bolts. (see securing bolt 1 in the drawing)
• Securing device (M5 x 25, 4.5 x 60 screws)
Now loosen the transport securing devices. The transport securing
devices are located:
• To secure the X axis - (securing device 2) angle brackets on each
side of the machine's base plate M4 x 10 screws
• To secure the Y axis - (securing device 3) on the left-hand side of
the plotter head M4 x 40 screws
• To secure the Z axis - (securing device 4) on the plotter head
M4 x 20 screw
Set up the circuit-board plotter so that the cables connecting the
electronics unit are free to move.
› Connect the LPKF
ProtoMat C30 (C30/S)
to COM1 or COM2 on the
computer using the null modem cable.
› Plug the LPKF
ProtoMat C30 (C30/S)
control unit into the electricity
supply.
Fit the vacuum system onto the adaptor
(fits pipe no. 111124 on a Nilfisk industrial vacuum system).
fig. 1:
Caution! The machine must stand on a flat and firm base in order to
work correctly and without malfunctions.
Note: Keep all transport securing devices and reattach them
accordingly if the machine is to be shipped again. The packaging
should also be kept and used when the machine is returned for
servicing.
1- To secure themachine to the transportation base (M5 x 25, 4.5 x 60 screws)
2- To secure the X axis (M4 x 10 screws)
3- To secure the Y axis (M4 x 40 screw)
4- To secure the plotter head (M4 x 20 screw)
4
1
2
3
Содержание ProtoMat C 30-S
Страница 72: ...Index 72 ProtoMat C30 C30 S...