7.8.2.6 Safety Function States
This section contains the variables related to the safety functions.
Name
UPID
Type
Value /
Bit
Significance Comments
Safety Fn
State Word
1A06h
UInt32
Bit 0
STO active
Same as UPID 1A10h
Bit 1
SS1 active
Same as UPID 1A11h
Bit 2
SOS active
Same as UPID 1A12h
Bit 3
SS2 active
Same as UPID 1A13h
Bit 4
SLS 0 active
Same as UPID 1A14h
Bit 5
SLS 1 active
Same as UPID 1A15h
Bit 6
SLS 2 active
Same as UPID 1A16h
Bit 7
SLS 3 active
Same as UPID 1A17h
Bit 8
Quick Stop ramp
down required
Same as UPID 1A18h
Bit 9
Abort ramp down
required
Same as UPID 1A19h
Bit 10
STO selected
Same as UPID 1A1Ah
Bit 11
SOS selected
Same as UPID 1A1Bh
Bit 12
SLS selected
Same as UPID 1A1Ch
Bit 13
Error active
Same as UPID 1A1Dh
Bit 14
Acknowledge is
required
Same as UPID 1A1Eh
Bit 15
Acknowledge
Error
Same as UPID 1A1Fh
Bit 16
Brake Released Same as UPID 1A20h
Bit 17
Brake Test Time
elapsed
Same as UPID 1A21h
Bit 18
SBT runs
Same as UPID 1A22h
Bit 19
Brake Test failed Same as UPID 1A23h
Bit 20
Drive
Temperature
Warning
Same as UPID 1A24h
Bits
21-31
-
not used
Safety Fn
State STO
1A10h
Bool
-
STO active
Set if the STO safety function is active and torque/force is removed from the drive.
The activation may be a result from a demand of the Safety Application Process of a
fault reaction from a fault in the safety fault buffer or a demand from the PROFIdrive
on PROFIsafe Safety Function State Machines.
Cleared if the STO safety function is inactive and torque/force may be generated
from the drive.
This bit can also be accessed via UPID 1A06h bit 0.