6.2.3.1.1 Motor cable
CAUTION
Do not connect or disconnect motor when there is power on the servo drive.
Use only double-shielded original LinMot cable. Cables from other sources must be checked precisely
before commissioning.
Incorrect connections can destroy the drive and stator.
CAUTION
Connectors and cables
The stator is connected to protective earth via the motor cable. The screw connections of the C and R
connectors must be tightened up to the stop.
Three types of cables are available for linear motors. The cable attached to the stator is not a high flex
cable. For moving cable applications, please use the special LinMot KS high flex (suitable for cable tracks)
or KR robot cable. See table below.
Standard cable
High-Flex cable
Robot cable
Cable Type *)
K05-04/05
K15-04/05
KS05-04/05
KS10-04/05
KR05-04/05
KR10-04/05
Minimum bending
radius for fixed
installation
25 mm
(1 in)
50 mm
(2 in)
30 mm
(1.2 in)
50 mm
(2 in)
40 mm
(1.6 in)
50 mm
(2 in)
Minimum bending
radius when moving
Not suitable for applications with
moving motor cable
60 mm
(2.4 in)
No torsion
100 mm
(4 in)
No torsion
80 mm
(3.2 in)
Max. Torsion:
±270° / 0.5 m
100 mm
(4 in)
Max. Torsion:
±270° / 0.5 m
Approval
-
UL / CSA 300 V
UL / CSA 300 V
UL / CSA 300 V
Material wire insulation
TPE-U
TPE-E
TPE-E
Material cable sheath
PUR
PUR
PUR
Oil resistance
very good
acc. DIN VDE 0282
Part 10 + HD 22.10
very good
acc. DIN VDE 0282
Part 10 + HD 22.10
very good
acc. DIN VDE 0282
Part 10 + HD 22.10
Chemical resistance (to
acids, alkalis, solvents,
hydraulic fluid)
good
good
good
Table 20: Cable list
*) For longer cables than 8 m use cable version 1V1.
2S Drive Systems / 0185-1174_E_1V1_SM_C1251-2S / NTI AG
0185-1174_E_1V1_SM_C1251-2S / 2021-11-26 16:43 (Rev. 12500)