10.3 Complete Acceptance Test
10.3.1 Documentation
Documentation of the machine and of safety functions
Machine description (with overview)
1.
Specification of the used safety components (such as drive, stator, slider)
2.
Function table:
3.
Active monitoring functions depending on the operating mode and the protective door.
a.
Other sensors with protective functions
b.
The table is part or is the result of the configuring work.
c.
Used safety functions for each drive.
4.
Information about safety equipment
5.
Drive configurations (safety and non-safety)
6.
HW configurations (e.g. ID switches, safe address switches)
7.
10.3.2 Functional and diagnostic safety tests
Detailed function test and evaluation of safety functions used. For some functions, trace recordings of individual
parameters can be used. If a listed function is not used, no test has to be performed.
Encoder parameterization test
1.
Check the configuration of the encoder (such as Type, pole pitch, …)
a.
Test the safety function "Safe Torque Off" (STO)
2.
Test of the SI function "Safe Stop 1" (SS1)
3.
Test of the SI function "Safe Brake Control" (SBC)
4.
Test of the SI function "Safe Stop 2" (SS2)
5.
Test of the SI function "Safe Operating Stop" (SOS)
6.
Test of the SI function "Safely-Limited Speed" (SLS)
7.
Test all used instances.
a.
Testing the "Safe Brake Test" (SBT) diagnostics function
8.
10.3.3 Conclusion of the Report
Report of the commissioning status tested and countersignatures:
Inspection of safety parameters
1.
Logging of checksums (for each drive)
2.
Issuing of the safety password and documenting this process (do not specify the safety password in the report!)
3.
Configuration backup and backup of the project
4.
Countersignature
5.
2S Drive Systems / 0185-1174_E_1V1_SM_C1251-2S / NTI AG