X3
Motor Phases
1
6
2
7
3
8
4
9
5
case
LinMot Motor:
Non-Safe Brake -
Non-Safe Brake+
Temp Sens+
Temp Sens-
+5VDC
AGND
Sensor Sine
Sensor Cosine
Mot Link P
Shield
EC Motor:
Non-Safe Brake -
Non-Safe Brake+
Temp Sens+
Temp Sens-
+5 VDC
AGND
Sensor Sine / Hall Switch U
Sensor Cosine / Hall Switch V
Hall Switch W
Shield
DSUB-9 (f)
Note:
Use +5 V (X3.3) and AGND (X3.8) only for motor internal hall sensor supply (max. 100 mA).
The motor cable length must not exceed 30 m.
Brake+: 24 V / max. 500 mA, Peak 1.4 A (will shut down if exceeded) the other terminal must be wired to Brake-
(X3.1)
Locking Screws:
Tightening torque 0.4 Nm
Caution:
Do NOT connect AGND (X3.8) to GND or earth!
Temperature Sensor:
A resistive temperature sensor (PT1000, KTY) can be connected between Temp Sens+ (X3.2) and Temp Sens-
(X3.7)
Important Notes:
Use Y-style motor cables only (for example K15-Y/C)! A W-style cable has a different shielding, so it cannot be
modified to a Y-style cable!
The motor cable length must not exceed 30 m
Table 9: X3 Connector: Motor Sensor / Non Safe Brake
2S Drive Systems / 0185-1174_E_1V1_SM_C1251-2S / NTI AG
0185-1174_E_1V1_SM_C1251-2S / 2021-11-26 16:43 (Rev. 12500)
Page 39 of 150