7.14 Safe Position Encoder
7.14.1 Description
For all position-based safety functions (SOS, SBC, SS2, SLS) a safe position encoder is necessary. As different motors
have different supervision configurations, the correct setting of the encoder type is necessary. The encoder type must be
configured in the parameter section.
WARNING
Sensor Wiring
The wiring to the sensor shall use the original NTI AG (LinMot) cable with a dedicated shielding.
The configuration parameters are located under: \Parameters\Safety\Encoder\
7.14.2 Parameters
Name
UPID
Type
Description
Encoder Type
47B2h
UInt8
The optional external encoder type can be selected.
Remark: To deactivate the use of an external encoder set the type to “Nonsafe”. The
parameter must not be displayed for the user but shall be part of the safety parameters.
00h: Nonsafe (Default)
02h: PS01-23x-HP
04h: PS01-37x-HP
05h: PS01-48x-LC
06h: PS01-48-HP
Encoder Direction
47B3h
UInt8
This parameter defines the direction, the safety module evaluates the safe position encoder
signals. If the direction is inverse to the non-safe direction, it can be inverted with this
parameter. The following selections can be done:
00h: Normal (Default)
01h: Inverse
Table 64: STO Parameters
7.14.2.1 Supported Safety Motors
Stator Type
Stator Article Number Description
Encoder Type
Selection
PS01-23x80F-HP-R-2S
0150-21259
Stator HP, IP67 with connector M17/9(m) - Safety
PS01-23x-HP
PS01-23x160H-HP-R-2S
0150-21254
Stator HP, IP67 with connector M17/9(m) - Safety
PS01-23x-HP
PS01-37x120F-HP-C-2S
0150-21251
Stator HP, IP67 with connector M23/9(m) - Safety
PS01-37x-HP
PS01-48x150G-HP-C-2S
0150-22992
Stator HP, IP67 with connector M23/9(m) - Safety
PS01-48-HP
PS01-48x240F-C-2S
0150-21220
Stator, IP67 with connector M23/9(m) - Safety
PS01-48x-LC
PS01-48x240F-HP-C-2S
0150-22991
Stator HP, IP67 with connector M23/9(m) - Safety
PS01-48-HP
Table 65: Supported safety motors
2S Drive Systems / 0185-1174_E_1V1_SM_C1251-2S / NTI AG
0185-1174_E_1V1_SM_C1251-2S / 2021-11-26 16:43 (Rev. 12500)
Page 96 of 150