C1251 Series single axis drive
Unit
C1251-MI-XC-2S-0E-xxx
Width
mm (in)
34 (1.4)
Height
mm (in)
206 (8.11)
Height with fixings
mm (in)
246 (9.69)
Depth
mm (in)
131 (5.16)
Weight
g (lb)
1100 (2.42)
Mounting Screws
Mounting Distance
mm (in)
2 x M5
228 (8.98)
Case, Degree of Protection
IP
20
mount in cabinet with at least IP54
Storage Temperature
°C
-25 to 40
Transport Temperature
°C
-25 to 70
Operating Temperature
°C
5 to 40
Relative humidity
% r.H.
10 to 85 (non-condensing)
Pollution
IEC/EN 60664-1
Pollution degree 2
Shock resistance (22 ms)
m/s
2
40, tested with 50
Vibration resistance (10 - 150 Hz)
m/s
2
1, tested with 10
Max. Case Temperature
°C
70
Max. Power Dissipation
W
30
Mounting place
In the control cabinet
Mounting position
vertical
Distance between Drives
mm (in)
20 (0.8) horizontal / 50 (2) vertical
Table 6: Drive physical dimension, mounting and environment
2S Drive Systems / 0185-1174_E_1V1_SM_C1251-2S / NTI AG
0185-1174_E_1V1_SM_C1251-2S / 2021-11-26 16:43 (Rev. 12500)
Page 35 of 150