5. Check the IBM support site for an applicable service bulletin or firmware update that applies
to this memory error.
6. If the problem stays with the original DIMM connector, re-inspect DIMM connector for foreign
material and remove, if found. If connector is damaged, replace system board.
7.
Remove the affected processor and inspect the processor socket pins for damaged or
mis-aligned pins. If damage is found, or this is an upgrade processor, replace the system board.
If there are multiple processors, swap them to move affected procesor to another processor
socket and retry. If problem follows the affected processor (or there is only one processor),
replace the affected processor.
8.
Replace the system board.
Related links
–
“Removing a memory module” on page 232
–
“Replacing a memory module” on page 233
–
“Removing a microprocessor and heat sink” on page 283
–
“Replacing a microprocessor and heat sink” on page 287
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
S.68005 [S.68005] An error has been detected by the IIO core logic on Bus %. The Global Fatal Error
Status register contains %. The Global Non-Fatal Error Status register contains %. Please check
error logs for the presence of additional downstream device error data. : Critical IOH-PCI Error
Severity
Error
User Response
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the IBM support site for an applicable service bulletin or firmware update for the system
or adapter that applies to this error.
3. If there are multiple Processors, swap Processors to move affected processor to another
processor socket and retry. If problem follows the affected processor, or this is a single processor
system, replace the processor. Inspect the processor socket on each processor removal and
replace system board first if the processor socket is damaged or mis-aligned pins are found.
4.
Replace the system board.
Related links
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
S.680B8 [S.680B8] Internal QPI Link Failure Detected. : Internal QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
Appendix C. UEFI/POST error codes
497
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...