Attention:
When you install an adapter, make sure that the adapter is correctly seated on the
system board connector before you turn on the server. An incorrectly seated adapter might cause
damage to the system board or the adapter.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Step 4.
Close the adapter retention latch.
Step 5.
Reconnect any cables that you disconnect earlier.
Step 6.
Perform any configuration tasks that are required for the adapter.
Step 7.
Replace the cover (see “Replacing the server top cover” on page 216).
Step 8.
Slide the server into the rack.
Step 9.
Reconnect the power cord and any cables that you removed.
Step 10. Turn on the peripheral devices and the server.
Removing a RAID adapter flash power module
Use this information to remove a RAID adapter flash power module.
If a RAID adapter flash power module is installed remotely in the server and you need to replace the RAID
adapter flash power module, complete the following steps:
Step 1.
Read the safety information and installation guidelines, see “Safety” on page v and “Installation
guidelines” on page 38.
Step 2.
Turn off the server (see “Turning off the server” on page 23) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
Step 3.
Remove the top cover (see “Removing the server top cover” on page 216).
Step 4.
Locate the battery/flash power module trays on top of the USB/video assembly (above the operator
information panel).
Step 5.
Press the tray retention clip tab to the right or left and remove the retention clip. See
Step 6.
Disconnect the flash power module cable from the failed flash power module and remove it from
the tray.
260
Lenovo System x3750 M4 Installation and Service Guide
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...