–
“Removing a memory module” on page 232
–
“Replacing a memory module” on page 233
–
“Removing a microprocessor and heat sink” on page 283
–
“Replacing a microprocessor and heat sink” on page 287
•
S.51009 [S.51009] No system memory has been detected. : No Memory Detected
Severity
Error
User Response
Complete the following steps:
1. If any memory errors are logged other than this one, take actions indicated for those codes first.
2. If no other memory diagnostic codes appear in the logs, verify that all DIMM connectors are
enabled using the Setup utility or the Advanced Settings Utility (ASU).
3. If the problem remains, shut down the system and physically verify that one or more DIMMs are
installed and that all DIMMs are installed in the correct population sequence.
4. If DIMMs are present and properly installed, check for any lit DIMM-connector LEDs, and if
found, reseat those DIMMs.
5. If the problem remains, replace the processor.
6. If the problem remains, replace the system board.
Related links
–
“Removing a memory module” on page 232
–
“Replacing a memory module” on page 233
–
“Removing a microprocessor and heat sink” on page 283
–
“Replacing a microprocessor and heat sink” on page 287
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
S.58008 [S.58008] A DIMM has failed the POST memory test. : DIMM Failed Memory Test
Severity
Error
User Response
Complete the following steps:
1. You must AC-cycle the system to re-enable the affected DIMM connector or re-enable manually
using the Setup utility.
2. If the system has been recently installed, serviced, moved, or upgraded, check to ensure
that DIMMs are firmly seated and that no foreign material can be seen in the DIMM connector.
If either condition is observed, correct and retry with the same DIMM. (Note: The event Log
might contain a recent 00580A4 event denoting detected change in DIMM population that
could be related to this problem.)
3. If the problem persists, replace the DIMM identified by LightPath and/or event log entry.
4. If the problem recurs on the same DIMM connector, swap the other DIMMs on the same
memory channel across channels one at a time to a different memory channel or processor. If
the problem follows a moved DIMM to a different memory channel, replace that DIMM.
496
Lenovo System x3750 M4 Installation and Service Guide
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...