• View the systems-management network interface port
• View the IMM2 MAC address
• View the current IMM2 IP address
• View the system Ethernet MAC addresses
• View the host name
• Define the static IMM2 IP address
• Define the subnet mask and gateway address
• Specify to use the static IP address or have DHCP assign the IMM2 IP address
• Enable or disable IP6 support
• Enable or disable Virtual Local Area Network (VLAN) support
• Advanced IMM2 Ethernet setup
• Save the network changes
–
Reset IMM to Defaults
Select this choice to reset the IMM2 to the default settings. All IMM2 settings are reset to the factory
default settings. This includes the IMM2 settings displayed in the setup screen. After the IMM2
configuration is cleared the IMM2 is restarted.
–
Reset IMM
Select this choice to restart the IMM2 settings.
–
Recovery
Select this choice to view or set the number of POST attempts and configure start recovery attempts.
–
POST attempts
Select this choice to view or set the number of attempts to POST before the recovery mechanisms
are started.
–
System Recovery
Select this choice to view or set the time to start the system recovery attempt.
•
POST Watchdog Timer
Select this choice to view or enable the POST watchdog timer. The default is
Disable
.
•
POST Watchdog Timer Value
Select this choice to view or set the POST loader watchdog timer value. The default is
5
.
•
Reboot System on NMI
Select this choice to enable or disable restarting the server whenever a nonmaskable interrupt
(NMI) occurs. The default is
Enabled
.
•
Halt On Server Error
Select this choice to prevent the server from booting the operating system and displaying the
POST event viewer when a severe error is detected during POST. The default is
Disable
.
–
Backup Bank Management
Select this choice to configure backup bank management settings.
•
Backup Bank Management Method
Select this choice to choose the Backup Bank Management Method. If
Auto Promotion
is
selected the IMM2 automatically updates the backup bank after the specified number of weeks
and successful consecutive boots have passed. If
User Managed
is selected the IMM2 will
not automatically update the backup bank.
Configuration information and instructions
139
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...