Related links
–
“Removing a memory module” on page 232
–
“Replacing a memory module” on page 233
•
I.580A6 [I.580A6] Memory spare copy has completed successfully. : Spare Copy Complete
Severity
Info
User Response
Complete the following steps:
Check system log for related DIMM failures and replace those DIMMs.
Related links
–
“Removing a memory module” on page 232
–
“Replacing a memory module” on page 233
•
S.1100C [S.1100C] An uncorrectable error has been detected on processor %. : Uncorrectable
processor error detected
Severity
Error
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot the system. If problem persists, contact Support.
•
S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %. : PCI SERR Detected
Severity
Error
User Response
Complete the following steps:
1. If this system and/or any attached cables were recently installed, moved, serviced or upgraded,
a. Reseat the adapter and any attached cables.
b. Reload the device driver.
c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe
Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2. Check the IBM support site for an applicable device driver, firmware update, or other information
that applies to this error. Load the new device driver and install any required firmware updates.
Appendix C. UEFI/POST error codes
489
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...