Appendix C. UEFI/POST error codes
This topic contains information about the UEFI/POST diagnostic error codes.
Note:
This documentation includes references to IBM web sites and information about obtaining service.
IBM is Lenovo's preferred service provider for the System x products.
UEFI/POST diagnostic error codes can be generated when the server starts or while the server is running.
UEFI/POST codes are logged in the IMM event log in the server.
For each event code, the following fields are displayed:
Event identifier
An identifier that uniquely identifies an event.
Event description
The logged message string that appears for an event.
Explanation
Additional information to explain why the event occurred.
Severity
An indication of the level of concern for the condition. The severity is abbreviated in the event log to the
first character. The following severities can be displayed.
Table 46. Event severity levels
Severity
Description
Informational
An informational message is something that was recorded for audit purposes,
usually a user action or a change of states that is normal behavior.
Warning
A warning is not as severe as an error, but if possible, the condition should be
corrected before it becomes an error. It might also be a condition that requires
additional monitoring or maintenance.
Error
An error typically indicates a failure or critical condition that impairs service or
an expected function.
User response
The actions that you should take to resolve the event.
Perform the steps in the order shown until the problem is solved. After you perform all of the actions that
are described in this field, if you cannot solve the problem, contact IBM Support.
The following is the list of the UEFI/POST error codes and suggested actions to correct the detected
problems.
List of UEFI events
This section lists all messages that can be sent from UEFI.
•
I.11002 [I.11002] A processor mismatch has been detected between one or more processors in
the system. : One or More Mismatched Processors Detected
© Copyright Lenovo 2016, and 2012, 2016
479
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...