a.
Make sure that the retention latch is in the open position.
b.
Connect any internal cables to the adapter.
c.
Insert the adapter into the connector, aligning the edge connector on the adapter with the
connector on the system board.
d.
Press the edge of the connector on the adapter
firmly
into the connector on the system board.
Make sure that the adapter snaps into connector securely.
Attention:
When you install an adapter, make sure that the adapter is correctly seated on
the system board before you turn on the server. An incorrectly seated adapter might cause
damage to the system board or the adapter.
e.
Close the adapter retention clip to secure the adapter in place.
f.
Go toStep 5 on page 224.
Step 4.
Install the new adapter on the PCIe riser-card assembly
,
a.
Make sure that the PCIe retention latch is in the open position.
b.
Connect any internal cables to the adapter.
c.
Insert the adapter into the riser-card assembly, aligning the edge connector on the adapter
with the connector on the riser-card assembly.
d.
Press the edge of the connector
firmly
into the riser-card assembly. Make sure that the adapter
snaps into the riser-card assembly securely.
Attention:
When you install an adapter, make sure that the adapter is correctly seated in the
riser-card assembly and that the riser-card assembly is securely seated in the riser-card
connector on the system board before you turn on the server. An incorrectly seated adapter
might cause damage to the system board, the riser-card assembly, or the adapter.
00000
00000
00000
00000
00
00
00
00
00
00
00
00
00
00
00
00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
00000
00000
00000
00000
00000
00000
00000
00000
PCI riser-card assembly
Adapter
e.
Close the adapter retention latch to secure the adapter in place.
f.
Install the riser-card assembly in the server (see “Replacing a PCI riser-card assembly” on
page 271).
Step 5.
Connect any external cables to the adapter, if necessary.
224
Lenovo System x3750 M4 Installation and Service Guide
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...