Step 5.
Install the power supply that comes with the power interposer card, (see “Installing a 1400-watt or
900-watt hot-swap power supply” on page 99) or ( “Installing a 750-watt -48 volt to -60 volt dc
power supply” on page 102).
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation” on
page 123.
Installing a USB embedded hypervisor flash device
Use this information to install a USB embedded hypervisor flash device.
To install a hypervisor flash device, complete the following steps:
Step 1.
Read the safety information and installation guidelines, see “Safety” on page v and “Installation
guidelines” on page 38.
Step 2.
Turn off the server (see “Turning off the server” on page 23) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables from the server.
Step 3.
Remove the top cover (see “Removing the server top cover” on page 40).
Note:
You might have to remove the PCIe riser-card assembly to access the USB (hypervisor)
connectors.
Step 4.
Locate the USB (hypervisor) connector on the system board in which you want to install the flash
device (see “System-board internal connectors” on page 28 for the location of the connectors for
the embedded hypervisor USB flash device).
Step 5.
Make sure that the lockbar on the USB (hypervisor) connector is in the unlock position (down).
Step 6.
Align the USB flash device with the connector on the system board and push it into the connector
until it is firmly seated.
Step 7.
Slide the lockbar up to the locked position until the lockbar is seated firmly.
107
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...