SAS signal
connector
Configuration
connector
SAS signal
connector
SAS power
connector
Notes:
• For more information about connecting the SAS signal cables to the drive backplane, see “Connecting
• You can install this drive backplane in backplane bays 1 and 2 or 3 and 4. It cannot be installed in
drive backplane bays 2 and 3. It is not supported.
To install the 8x2.5-inch hot-swap drive backplane, complete the following steps:
Step 1.
Read the safety information and installation guidelines, see “Safety” on page v and “Installation
guidelines” on page 38.
Step 2.
Turn off the server (see “Turning off the server” on page 23) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables from the server.
Step 3.
Remove the top cover (see “Removing the server top cover” on page 40).
Step 4.
Remove the fan cage assembly (see “Removing the fan cage assembly” on page 44).
Step 5.
Remove the microprocessor and memory expansion tray (see “Removing the microprocessor and
memory expansion tray assembly” on page 292) or DIMM air baffle (see “Removing the DIMM air
baffle” on page 220), whichever one is installed.
Step 6.
Open the SAS cable guide cover.
Step 7.
If a backplane filler panel is installed in the backplane bay in which you are installing the backplane,
remove the backplane filler panel.
Step 8.
Connect the two 10x2-pin power connectors on the combination power/configuration cable to
the backplane power connectors on the system board. The power connector on the end of the
black cable (which might be labelled 1/3) connects to backplane connector 1 or 3 on the system
board. The power connector on the end of the gray cable (which might be labelled 2/4) connects to
backplane connector 2 or 4 on the system board. Connect the configuration connector on the
combination power/configuration cable to the configuration connector on the drive backplane.
Connect the other power connector on the combination power/configuration cable to the power
connector on the backplane.
Note:
You can connect the cables to the backplane before you install the backplane onto the cage,
or you can connect the cables after you install the backplane, if that is easier for you.
112
Lenovo System x3750 M4 Installation and Service Guide
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......