Group 8
Job Editor
Page 89
JET3up
Release R1.06
6.7
Optional equipment
6.7.1
External head print ventilation - assembly and function
Function:
External head ventilation is predominantly used for devices in safety class IP65 and
for print jobs in which the retractive suction of particles (e.g. paper lint in the
printing industry) in printer circulations should be avoided.
For this purpose, the unit is provided with a
head ventilation
and a
housing
ventilation
:
Head ventilation:
The printer's print head is impinged on with a constant air flow
of 30l/h and thus the retractive suction of particles is prevented.
Housing ventilation:
With devices of protection class IP65, a great deal of heat
is generated due to the tight design of the housing. Due to this heat generation
in conjunction with the evaporation of the operating materials, an explosion
danger zone (Ex zone) can arise.
To prevent this, the interior space of the hydraulic housing is impinged on with a
constant air flow of 70l/h and vented via a concealed drilled hole.
Assembly:
1.
Outside of the rear panel of the housing:
The unit's pressure regulator valve is attached to the outside.
2.
Inside of the rear wall of the housing:
Both of the throttle valves for the writing head ventilation and the housing
ventilation are attached to the inside. These valves are adjusted exactly as well
as sealed and may
not
be adjusted!
CAUTION – INSTALLATION OF PRINT HEAD
Both of the throttle valves are adjusted exactly and may not be
adjusted!
ATTENTION
Make sure that there is a permanent compressed air supply!
The printer doesn’t monitor the permanent compressed air supply!
There will be no warning in case the permanent compressed air
supply fails!
Operation is only permissible with dry, oil-free and filtered
compressed air (Filtering 8
µ
m) The use of otherwise prepared
compressed air can lead to damage and malfunctions!
Содержание JET3 up
Страница 1: ...Operating Manual V1 06 Please keep for future reference ...
Страница 2: ......
Страница 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Страница 22: ...Page 20 Safety Group 2 Release R1 06 JET3up 2 4 Safety sticker Figure 1 Safety sticker Safety sticker ...
Страница 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Страница 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Страница 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Страница 386: ...Page 384 Appendix Connection Examples for the Interfaces Group 12 Release R1 06 JET3up Interface X3 Outputs ...
Страница 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Страница 397: ...Group 12 Appendix List of illustrations Page 395 JET3up Release R1 06 12 4 3 Print head SK 4 Option ...
Страница 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...