Group 8
Job Editor
Page 135
JET3up
Release R1.06
Proceeding:
Press on the tab
< Interfaces>
(2)
to select the tab.
Press on the arrow key of the drop-down list
<Encoder Settings>
(3)
. The
drop-down list opens for selection.
Now select the required interface.
If required activate now the bounce time delay by clicking on the check box
(4)
.
An activated delay is displayed by
√
in the check box.
Figure 50
Select encoder interface
Bounce time delay is switched off
Bounce time delay is switched on
1 –Dialog box <Basic Settings>
3 – Drop-down list <Encoder settings>
2 –Tab < Interfaces>
4 – Check box <Bounce time delay off>
Pos. Interface
Describtion
1.
RS422
5V / 4 Signals (A,
Ā
, B, B)
2.
TTL
5V TTL / 2 Signals (A, B)
3.
HTL
24V / 2 Signals (A, B)
2
1
3
4
Содержание JET3 up
Страница 1: ...Operating Manual V1 06 Please keep for future reference ...
Страница 2: ......
Страница 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Страница 22: ...Page 20 Safety Group 2 Release R1 06 JET3up 2 4 Safety sticker Figure 1 Safety sticker Safety sticker ...
Страница 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Страница 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Страница 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Страница 386: ...Page 384 Appendix Connection Examples for the Interfaces Group 12 Release R1 06 JET3up Interface X3 Outputs ...
Страница 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Страница 397: ...Group 12 Appendix List of illustrations Page 395 JET3up Release R1 06 12 4 3 Print head SK 4 Option ...
Страница 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...