48
ENGLISH
DEFECT
CAUSE
SOLUTION
9.
Autolevel alarm.
t/PXBUFSJOBVUPNBUJDMFWFM
water circuit.
t5IFNBJOTXBUFSTVQQMZWBMWF
is closed.
t"VUPMFWFMFMFDUSPNBHOFUJD
valve is defective.
t$IFDLUIBUUIFNBJOTXBUFSTIVUPGG
valve is open.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must inspect the automatic level
water circuit and check the operation
of the solenoid, and replace it if
necessary.
10.
Overfill alarm.
t$JSDVJUBVUPNBUJDMFWFM
malfunction, the filling solenoid
is always open.
t5IFNBOVBMýMMJOHWBMWFJT
faulty.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must check the correct operation of
the filling solenoid, the electronics
controlling the automatic level and
any faults in the manual filling valve.
11.
The machine is on (main
switch in position 1 or
2 and the indicator light
is on) but the electronic
control is out of service.
t5IFFMFDUSJDBMXJSJOHPGUIF
electronic board or touch panel
is defective.
t5IFFMFDUSPOJDCPBSEPSUPVDI
panel are defective.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must check the electrical wiring
of the electronic board and touch
panel. Check the operation of the
electronic board and touch panel and
replace any defective components if
necessary.
12.
The machine delivers
water from a brewing
group even if no coffee
dose buttons have been
selected.
t5IFCSFXJOHHSPVQTPMFOPJE
and/or pump are powered
continuously.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must check the electronic board and
the touch panel. Check the operation
of the electronic board and touch
panel and replace any defective
components if necessary.
13.
The steam wand drips
slightly, even when in the
closed position.
t4UFBNWBMWFHBTLFUJTXPSO
t5IFWBMWFOFFETUPCF
adjusted.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must check the gasket and replace if
necessary or adjust the steam valve.
14.
The hot water spout
drips slightly, even if in
the closed position.
t)PUXBUFSWBMWFHBTLFUJTXPSO
t5IFWBMWFOFFETUPCF
adjusted.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must check the gasket and replace
if necessary, or adjust the hot water
valve.
15.
The unit whistles after
brewing a coffee.
t%FGFDUJWFDIFDLWBMWF
t)JHIQVNQQSFTTVSF
t*OTQFDUUIFDIFDLWBMWFBOESFQMBDF
if necessary. Calibrate the valve to 12
bar.
t5IFBVUIPSJ[FERVBMJýFEUFDIOJDJBO
must check the pump operating
pressure. Calibrate the pump to 9 bar.
Содержание 20/20 CLASSIC Series
Страница 2: ...ITALIANO USO E MANUTENZIONE SERIE 20 20 CLASSIC Istruzioni originali ...
Страница 9: ...8 ITALIANO 2 2 Schema generale del sistema idraulico ...
Страница 28: ...ENGLISH USE AND MAINTENANCE 20 20 CLASSIC SERIES Draft of the original instructions ...
Страница 35: ...34 ENGLISH 2 2 General water system diagram ...
Страница 52: ...FRANÇAIS EMPLOI ET ENTRETIEN SÉRIE 20 20 CLASSIC Traduction des instructions originales ...
Страница 59: ...58 FRANÇAIS 4DIÏNB IZESBVMJRVF HÏOÏSBM ...
Страница 78: ...DEUTSCH BEDIENUNG UND WARTUNG SERIE 20 20 CLASSIC Übersetzung der Original Anleitungen ...
Страница 85: ...84 DEUTSCH 2 2 Allgemeiner Wasseranschlussplan ...