Machine Controls Section
3-13
Commander III Operation Manual
About the Main Control Section
Home Machine
This button starts the home sequence on the machine,
which scans to find a physical reference point on the
frame. When this point is found, the position is stored and
then used to calculate the location of all moves during the
machine process. The home sequence must be performed
every time the machine is powered up or reset.
Reset Machine
If a fault occurs that cannot be cleared, press the
Reset
Machine
button. This button will reset the machine to the
start position.
Important:
Press the
Home
button
after resetting the
machine
Setup Mode On/Off
Select
Setup Mode
to toggle on or off. In the
On
mode, a
safe mode is active. The machine will go through normal sequences except the cutting
motors will be inactive. Use this mode to check the machine operation without making a
cut on the door. With the setup mode set to on, the button will change to an orange back-
ground.
In the
Off
mode the machine is in normal operation.