About the Calibration Screens
KVAL Commander III Operation Manual
4-24
Door and Jamb Depth Adjustment Mapping
If doors and jambs are straight, this section should
not
be used. However, if the doors and jambs
are not straight, the Depth Adjustment Mapping Menu allows you to compensate by changing the
depth of the routers and chisels at the location of the flaw.
Note:
If a door is out of calibration on a particular hinge, make sure there is no dust
behind the H-block where the door and jamb is clamping against.If there is no
dust and the depth is shallow on one hinge, changes can be made to adjust the
hinge depth on one particular pocket
Process a Right Hand Door
The Depth Mapping is divided into 15 inch sections from 0 to 90” and has a section for
over 90”locations.
1.
Find the position where the hinge is out of specification
2.
Note the value of how much the measurement of the out of specification (too deep
or too shallow)
3.
Measure from the head of the door and find what location the out of specification
hinge is located.
4.
On the Mapping Menu, select the section the hinge is located and enter or combine
with number in the box.For example if the hinge pocket is too deep enter a negative
number to adjust the routers. If it is too shallow, enter a positive number to adjust
the routers.
5.
Machine another door and repeat until offset is corrected
Содержание Commander III
Страница 29: ...How to Download the Service Application 1 19 KVAL Commander III Operation Manual Page Intentionally Left Blank ...
Страница 46: ...About Revisions 2 16 KVAL Manual ...
Страница 81: ...Common Terms 2 51 KVAL Manual FIGURE 2 11 Example of a Validation Report ...
Страница 162: ...Options KVAL Commander III Operation Manual 5 20 ...
Страница 165: ......
Страница 166: ......
Страница 167: ......