About the Calibration Screens
KVAL Commander III Operation Manual
4-22
About Lock Plate Timing Calibration
Vertical:
If the vertical time is not making it up or down, before the horizontal move starts, enter a larger
number. This number is in seconds. If there is a delay before the horizontal moves, enter a smaller
number in this box.
Horizontal
:
If the Horizontal time is not making it left or right, before the vertical move starts, enter a larger
number. This number is in seconds. If there is a delay before the vertical moves, enter a smaller
number in this box.
Feed System Timing
Calibrates the In-feed and Out-feed timing of the door into the machine. Adjust until the Stop tim-
ing with the door is in synchronization.