22
Repairs, maintenance and settings by technicians
22.20 Checking/setting sensor B22 “Bale on table”
350
BiG Pack 1270
Original Operating Instructions 150000747_02_en
Checking
Press the bale (2) until it has completely left the bale channel (1).
Æ
The signal sheet (3) completely covers the sensor (4).
Æ
The sensor (4) is attenuated (there is iron in front of the sensor).
ü
The machine is shut down and safeguarded,
.
Check dimension X between the signal sheet (3) and the sensor (4).
Æ
If the dimension is
X= 2-3 mm
, the setting is correct.
Æ
If the dimension
is not X= 2-3 mm
, the sensor must be set.
Setting
Loosen the nuts (5) on both sides of the sensor (4).
Turn the nuts (5) until dimension
X=2-3 mm
is reached.
Tighten the nuts (5) (tightening torque = 10 Nm).
During the sensor test check that the sensor (4) is attenuated,
Æ
The sensor has been set correctly if the sensor test shows that the sensor is attenuated.
Æ
If the sensor test shows that the sensor is unattenuated, set the sensor until the sensor test
shows that the sensor is attenuated.