21
Malfunction, cause and remedy
21.1
Malfunctions electrics/electronics
266
BiG Pack 1270
Original Operating Instructions 150000747_02_en
522114-
B17
Sensor B17 “Baling flap pressure“
Possible cause
Remedy
FMI 2: The data is not permitted.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522115-
B12
Sensor B12 “Bale ejection“
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522116-
B14
Sensor B14 “Bale ejector“
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522117-
B15
Sensor B15 “Star wheel“
Possible cause
Remedy
FMI 2: The data is not permitted.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522118-
B23
Sensor B23 "Pick-up position"
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
Содержание Big Pack 1270
Страница 360: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 362: ...B17 K9 K11 K12 1 2 3 K13 1 3 2 4 B B1 A A1 1 2 5 3 4 150101911_00 3 4 ...
Страница 364: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 366: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...
Страница 438: ...438 BiG Pack 1270 Original Operating Instructions 150000747_02_en This page has been left blank deliberately ...