21
Malfunction, cause and remedy
21.1
Malfunctions electrics/electronics
252
BiG Pack 1270
Original Operating Instructions 150000747_02_en
522011-
Blade cassette is down
Possible cause
Remedy
FMI 2: The data is not permitted.
In "road travel" mode the
blade cassette is down.
Raise the blade cassette.
522012-
Blade cassette is down
Possible cause
Remedy
FMI 2: The data is not permitted.
When the machine is starting
up, the blade cassette is
down.
Raise the blade cassette.
522013-
S1
Momentary switch “Raise blade cassette"
Possible cause
Remedy
FMI 2: The data is not permitted.
The momentary switch is
sticking.
Eliminate the cause of the momentary switch sticking.
Replace the momentary switch.
522014-
S2
Momentary switch “Lower blade cassette"
Possible cause
Remedy
FMI 2: The data is not permitted.
The momentary switch is
sticking.
Eliminate the cause of the momentary switch sticking.
Replace the momentary switch.
522015-
>MAX
Baling flap pressure
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The baling flap pressure is too
high.
Switch off the PTO shaft.
Check the pressure limiting valve for crop blockage.
Replace the pressure sensor.
522016-
Flywheel brake
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
The flywheel brake is applied
when the KMC starts.
Release the flywheel brake.
Содержание Big Pack 1270
Страница 360: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 362: ...B17 K9 K11 K12 1 2 3 K13 1 3 2 4 B B1 A A1 1 2 5 3 4 150101911_00 3 4 ...
Страница 364: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 366: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...
Страница 438: ...438 BiG Pack 1270 Original Operating Instructions 150000747_02_en This page has been left blank deliberately ...