Terminal – Menus
13
Menu 15 "Settings" 13.16
BiG Pack 1270
Original Operating Instructions 150000747_02_en
181
Possible status displays of the actuators
Icon
Designation
1
Actuator ON
2
Actuator OFF
3
General actuator error
4
No supply voltage
Possible cause: Fuse defective.
Diagnostics for digital actuators
15-2
state: 2
OFF
K01
K02
EQG000-019
Errors are only displayed if the actuator is turned on and a test for the actuator in question is
available. The LED on the plug can also be checked directly on the actuator.
Press
to switch the actuator on.
Press
to switch the actuator off.
Diagnostics for analogue actuators
15-2
state: 1
ON
PWM:
300
I=
0mA
K02
K11
K31
EQG000-020
A current (in mA) can be set with the PWM value (in parts per thousand).
With a value of PWM = 500, the current should be between 500 mA and 3000 mA (depending
on the valve that is used and the operating temperature).