150
10/100Mbps link Amber off)
Pwr: Power Ready ( Green On)
Sys: System Ready (Green On), System on booting/update (Green Blinking)
DI/DO: Digital Input (RED On), Dry Relay Active (RED On)
R.S.: Green on (Ring normal)/Blinking (wrong ring port connective), Amber on (Ring
abnormal) / Blinking (device’s ring port failed)
Power Requirement
System Power
Redundant Power Input: DC 24V (typical ); Input voltage range (10~60Vdc)
Power Consumption
10Watts/DC12V, 11Watts / DC24V, 14Watts/DC48V, 16Watts/DC60V
Mechanical
Installation
EN50022 DIN Rail Mounting
Enclosure Material
Steel Metal with Aluminum
Ingress Protection
IP-30
Dimension (HxWxD)mm
160 (H) x 108 (W) x 127 (D) without DIN Rail Clip
160 (H) x 108 (W) x 136 (D) with DIN Rail Clip
Environmental
Operating Temperature
-40
°C
~75°C
Operating Humidity
0%~90%, Non-Condensing
Storage Temperature
-40°C~80°C
Hi-Pot Insulation
AC 1.2KV for Ethernet Interface to Power, Power to Chassis Ground, Ethernet Interface
to Chassis Ground
Approvals
EMC
EMI: IEC/EN61000-6-2, EN55022
EMI:
FCC Class A, CE
EMI:
Radiation, Conduction
EMS: IEC/EN61000-6-4
IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6,
IEC61000-4-8, IEC61000-4-9
Vibration
IEC 60068-2-6 : 10~150Hz,20m/S
2
,20 Sweeps/Axis
Shock
IEC 60068-2-27: 50gn,18ms,Half-Sine wave
Free Fall
IEC 60068-2-32: 1 corner, 3 line, 6faces
Warranty