Field Service Ver. 2.0 Mar. 2006
6. Periodical check
11
bizhub C250P
Maintenance
Maintenance
6.
Periodical check
6.1
Service schedule
Guarantee period (5-year or 600,000 prints)
6.2
Maintenance items
6.2.1
Parts to be replaced by users (CRU)
*1: Also replace the Dust Filter/Cooling Fan packed in the Waste Toner Box at the same
time when the Waste Toner Box is replaced.
*2: Also replace the Deodorant Filter packed in the Toner Cartridge K at the same time
when 20 K is reached.
*3: The parts can be replaced either by User or Customer Engineer.
See P.187
*4: A waste toner full condition is detected with detecting the actual waste toner emissions.
Per cycle
×
print number
×
10,000-print
Number
of times
12
20
24
30
36
40
48
Main Unit
120,000
●
●
●
●
4
200,000
●
●
2
300,000
●
1
PC-103
PC-203
PC-403
300,000
●
1
FS-501
FS-603
300,000
●
1
No.
Class
Parts to be replaced
Cycle
Clean Replace Descriptions
1
Processing
sections
Imaging Unit C/M/Y
45 K
●
*3
2
Imaging Unit K
70 K
●
*3
3
Dust filter/Cooling Fan
30 K
●
*1
4
Comb electrode
When TC K is replaced
●
5
Toner cartridge: TC
(TC Y/TC M/TC C)
12 K
●
*3
6
Toner cartridge: TC
(TC K)
20 K
●
*2, 3
7
Fusing section Deodorant filter
20 K
●
*2
8
Image Trans-
fer section
Waste Toner Box
(25 K)
●
*1, 3, 4
bizhub_C250P_Total.book 11 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......