14. User Setting
Field Service Ver. 2.0 Mar. 2006
176
bizhub C250P
Adjustment / Setting
(6) Encryption Key
• It can be set only when the optional Security Kit (SC-503) is mounted.
14.3.11
OpenAPI
A. Access Setting
B. Port No.
1
Functions
• To set Encryption key necessary to mount the optional Security Kit SC-503.
Use
• To setup Security Kit SC-503.
• To re-set encrypting word due to exchange of NVRAM board or etc.
NOTE
• This setting is available only when the optional Security Kit SC-503 is
mounted.
• HDD formatting is required after this setting. Therefore it is necessary to
retrieve certain data from HDD in advance.
The following data will be lost after HDD formatting.
* Address data
* Authentication data
: Authentication mode, User Authentication setting,
Account Track setting
* Box setting data
: Box and text in the box, Setting information of each
box, Box for Fax
* Job history, Fax transmission history
Setting/
Procedure
1.
Enter the Encryption key. (consisting of up to 20 characters)
NOTE
• Double-byte and identical characters are not acceptable.
2.
Press the Menu/Select key. (Go to step 7 for the initial registration.)
3.
If the Encryption Key is changed, enter a new encryption word (consisting of up to
20 characters).
4.
Press the Menu/Select key.
5.
If the Encryption Key is changed, enter the new encryption word (consisting of up to
20 characters) a second time.
6.
Press the Menu/Select key.
7.
Turn off the Main Power Switch and turn it on again more than 10 seconds after.
8.
Select [Admin. Setting]
→
[Security Setting] and perform HDD Format.
9.
Turn off the Main Power Switch and turn it on again more than 10 seconds after.
Functions
• To allow or restrict the access from other systems with OpenAPI when using Page
Scope Data Administrator.
Use
• To restrict access from other systems with OpenAPI.
Setting/
Procedure
• The default setting is Permit.
“Permit”
Prohibit
Functions
• To set the access port for other systems with OpenAPI when using Page Scope Data
Administrator.
Use
• To change the access port number for other systems with OpenAPI.
Setting/
Procedure
• Enter the port number between 1 and 65535.
bizhub_C250P_Total.book 176 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......